Hitran named supplier of the year for 2010
|
Line Reactors
![]() |
Download PDF: click here |
View as Webpage: click here |
HITRAN's standard line reactors are designed to minimize the problems associated with waveform distortion that occurs with equipment utilizing solid state switching devices.
Line Reactors are often used to · Reduce harmonics · Extend solid state switching device life · Reduce motor noise and temperature · Improve power factor · Filter power line irregularities · Reduce surge currents
Reactors are available in either 3% or 5% ratings. Typically a 3% reactor will be sufficient to handle most solid state switching applications and will filter normal line spikes and surges. Nuisance circuit breaker tripping can usually be avoided. A 5% reactor should be used where considerably higher line disturbances exist and compliance with IEEE 519 is desired. The 5% reactor is also the most effective at improving motor life by reducing the effects of harmonic currents.
Line Reactors |
|
HITRAN's standard line reactors are designed to minimize the problems associated with waveform distortion that occurs with equipment utilizing solid state switching devices.
Line Reactors are often used to… • Reduce harmonics • Extend solid state switching device life • Reduce motor noise and temperature • Improve power factor • Filter power line irregularities • Reduce surge currents
Reactors are available in either 3% or 5% ratings. Typically a 3% reactor will be sufficient to handle most solid state switching applications and will filter normal line spikes and surges. Nuisance circuit breaker tripping can usually be avoided. A 5% reactor should be used where considerably higher line disturbances exist and compliance with IEEE 519 is desired. The 5% reactor is also the most effective at improving motor life by reducing the effects of harmonic currents.
All Hitran line reactors can be used as either input or output reactors.
INPUT SIDE OF DRIVE | OUTPUT SIDE OF DRIVE |
When reactors
are installed on the input side of drives, they reduce harmonic
distortion from the drive onto the line. This installation setup
will also limit voltage and current spikes and surges from the
incoming line and reduces line notching. |
By installing
the reactor on the output side of the drive, the motor performance
improves. This setup will improve the current and voltage waveforms
from the supply, hence the noise emissions and motor overheating
will be reduced. This installation will also protect the drive
from short circuits at the load |
![]() |
![]() |
MULTIPLE DRIVES | MULTIPLE MOTORS |
When multiple
drives are installed on the power line, individual line reactors
are recommended. Individual reactors provide isolated protection
for each drive's own specific load and eliminates cross talk
between multiple drives. |
When there
is a need for multiple motors on the same drive, a single reactor
can be used. This application is for simultaneous operating
motors only. The size of the reactor is based on the sum of
horsepower of all motors |
![]() |
![]() |
Hitran |
iAMPS |
LMH |
VOLTAGE |
||||||||||
208 |
240 |
380 |
415 |
480 |
600 |
||||||||
AP2111 |
2 |
12.0 |
- |
- |
4% - 1HP |
- |
3% - 1-1½HP |
- |
|||||
AP2112 |
2 |
20.1 |
- |
- |
- |
4% - 1HP |
5% - 1-1½HP |
3% - 1 - 1½HP |
|||||
AP2113 |
2 |
32.1 |
- |
- |
- |
- |
- |
5% - 1 - 1½HP |
|||||
AP2114 |
4 |
3.1 |
3% - 1HP |
3% - 1HP |
- |
- |
- |
- |
|||||
AP2115 |
4 |
6.5 |
5% - 1HP |
5% - 1HP |
- |
- |
3% - 2-3HP |
- |
|||||
AP2116 |
4 |
9.1 |
- |
- |
4% - 1½-2HP |
4% - 2HP |
5% - 2-3HP |
3% - 3 - 5HP |
|||||
AP2117 |
4 |
12.0 |
- |
- |
- |
4% -1½HP |
- |
5% - 2 - 3HP |
|||||
AP2118 |
8 |
1.5 |
3% - 1½-2HP |
3% - 1½-2HP |
- |
- |
- |
- |
|||||
AP2119 |
8 |
3.1 |
5% - 1½-2HP |
5% - 1½-2HP |
- |
- |
3% - 5HP |
3% - 7½HP |
|||||
AP2120 |
8 |
5.1 |
- |
- |
4% - 3HP |
- |
5% - 5HP |
3% - 5HP / 5% - 7½HP |
|||||
AP2121 |
8 |
7.5 |
- |
- |
- |
4% - 3HP |
- |
5% - 5HP |
|||||
AP2122 |
12 |
1.25 |
3% - 3HP |
3% - 3HP |
- |
- |
- |
- |
|||||
AP2123 |
12 |
2.6 |
5% - 3HP |
5% - 3HP |
4% -7½HP |
3% - 7½HP |
3% - 10HP |
||||||
AP2124 |
12 |
4.25 |
- |
- |
4% - 5HP |
- |
5% - 7½HP |
5% - 10HP |
|||||
AP2125 |
18 |
0.81 |
3% - 5HP |
3% - 5HP |
- |
- |
- |
- |
|||||
AP2126 |
18 |
1.6 |
5% - 5HP |
5% - 5HP |
4% - 10HP |
3% - 10HP |
3% - 15HP |
||||||
AP2127 |
18 |
2.5 |
- |
- |
- |
4% - 10HP |
5% - 10HP |
5% - 15HP |
|||||
AP2128 |
25 |
0.5 |
3% - 7½HP |
3% - 7½HP |
- |
- |
- |
- |
|||||
AP2129 |
25 |
1.2 |
5% - 7½HP |
5% - 7½HP |
4% - 15HP |
4% - 15HP |
3% - 15HP |
3% - 20 - 25HP |
|||||
AP2130 |
25 |
2.0 |
- |
- |
- |
- |
5% - 15HP |
5% - 20 - 25HP |
|||||
AP2131 |
35 |
0.40 |
3% - 10HP |
3% - 10HP |
- |
- |
- |
- |
|||||
AP2132 |
35 |
0.81 |
5% - 10HP |
5% - 10HP |
- |
4% - 25HP |
3% - 20 - 25HP |
3% - 30HP |
|||||
AP2133 |
35 |
1.2 |
- |
- |
4% - 20HP |
4% - 20HP |
5% - 20 - 25HP |
5% - 30HP |
|||||
AP2134 |
45 |
0.30 |
3% - 15HP |
3% - 15HP |
- |
- |
- |
- |
|||||
AP2135 |
45 |
0.71 |
5% - 15HP |
5% - 15HP |
4% - 25 - 30HP |
4% - 30HP |
3% - 30HP |
3% - 40HP |
|||||
AP2136 |
45 |
1.2 |
- |
- |
- |
- |
5% - 30HP |
5% - 40HP |
|||||
AP2137 |
55 |
0.25 |
3% - 20HP |
3% - 20HP |
- |
- |
- |
- |
|||||
AP2138 |
55 |
0.51 |
5% - 20HP |
5% - 20HP |
- |
4% - 40HP |
3% - 40HP |
3% - 50HP |
|||||
AP2139 |
55 |
0.85 |
- |
- |
- |
- |
5% - 40HP |
5% - 50HP |
|||||
AP2140 |
80 |
0.20 |
3% - 25HP |
3% - 25 - 30HP |
- |
- |
- |
- |
|||||
AP2141 |
80 |
0.41 |
5% - 25HP |
5% - 25 - 30HP |
4% - 40 - 50HP |
4% - 50 - 60HP |
3% - 50 - 60HP |
3% - 60 - 75HP |
|||||
AP2142 |
80 |
0.7 |
- |
- |
- |
- |
5% - 50 - 60HP |
5% - 60 - 75HP |
|||||
AP2143 |
100 |
0.15 |
3% - 30HP |
3% - 40HP |
- |
- |
- |
- |
|||||
AP2144 |
100 |
0.31 |
5% - 30HP |
5% - 40HP |
4% - 60HP |
4% - 75HP |
3% - 75HP |
3% - 100HP |
|||||
AP2145 |
100 |
0.45 |
- |
- |
- |
- |
5% - 75HP |
5% - 100HP |
|||||
AP2146 |
130 |
0.10 |
3% - 40HP |
3% - 50HP |
- |
- |
- |
- |
|||||
AP2147 |
130 |
0.21 |
5% - 40HP |
5% - 50HP |
- |
4% - 100HP |
3% - 100HP |
3% - 125HP |
|||||
AP2148 |
130 |
0.30 |
- |
- |
4% - 75HP |
5% - 100HP |
5% - 125HP |
||||||
AP2149 |
160 |
0.75 |
3% - 50HP |
3% - 60HP |
- |
- |
- |
- |
|||||
AP2150 |
160 |
0.16 |
5% - 50HP |
5% - 60HP |
- |
- |
3% - 125HP |
3% - 150HP |
|||||
AP2151 |
160 |
0.23 |
- |
- |
4% - 100HP |
- |
5% - 125HP |
5% - 150HP |
|||||
AP2152 |
200 |
0.055 |
3% - 60HP |
3% - 75HP |
- |
4% - 125HP |
- |
- |
|||||
AP2153 |
200 |
0.12 |
5% - 60HP |
5% - 75HP |
- |
- |
3% - 150HP |
3% - 200HP |
|||||
AP2154 |
200 |
0.185 |
- |
- |
4% - 125HP |
4% - 150HP |
5% - 150HP |
5% - 200HP |
|||||
AP2155 |
250 |
0.045 |
3% - 75HP |
3% - 100HP |
- |
- |
- |
- |
|||||
AP2156 |
250 |
0.095 |
5% - 75HP |
5% - 100HP |
- |
4% - 200HP |
3% - 200HP |
3% - 250HP |
|||||
AP2157 |
250 |
0.150 |
- |
- |
4% - 150HP |
- |
5% - 200HP |
5% - 250HP |
|||||
AP2158 |
320 |
0.040 |
3% - 100HP |
3% - 125HP |
- |
- |
- |
- |
|||||
AP2159 |
320 |
0.080 |
5% - 100HP |
5% - 125HP |
- |
- |
3% - 250HP |
3% - 300HP |
|||||
AP2160 |
320 |
0.125 |
- |
- |
4% - 200HP |
- |
5% - 250HP |
5% - 300HP |
|||||
AP2161 |
400 |
0.030 |
3% - 125HP |
3% - 150HP |
- |
- |
- |
- |
|||||
AP2162 |
400 |
0.060 |
5% - 125HP |
5% - 150HP |
- |
4% - 300HP |
3% - 300HP |
3% - 350 - 400HP |
|||||
AP2163 |
400 |
0.105 |
- |
- |
4% - 250HP |
4% - 250HP |
5% - 300HP |
5% - 350 - 400HP |
|||||
AP2164 |
500 |
0.025 |
3% - 150HP |
3% - 200HP |
- |
- |
- |
- |
|||||
AP2165 |
500 |
0.050 |
5% - 150HP |
5% - 200HP |
4% - 350HP |
4% - 350HP |
3% - 350 - 400HP |
3% - 500HP |
|||||
AP2166 |
500 |
0.085 |
- |
- |
4% - 300HP |
- |
5% - 350 - 400HP |
5% - 500HP |
|||||
AP2167 |
600 |
0.020 |
3% - 2005HP |
3% - 250HP |
- |
- |
- |
- |
|||||
AP2168 |
600 |
0.040 |
5% - 200HP |
5% - 250HP |
- |
- |
3% - 500HP |
3% - 600HP |
|||||
AP2169 |
600 |
0.065 |
- |
- |
4% - 400HP |
4% - 400HP |
5% - 500HP |
5% - 600HP |
|||||
AP2170 |
750 |
0.015 |
3% - 250HP |
3% - 300HP |
- |
- |
3% - 600HP |
- |
|||||
AP2171 |
750 |
0.029 |
5% - 750HP |
5% - 300HP |
- |
- |
- |
3% - 750HP |
|||||
AP2172 |
750 |
0.048 |
- |
- |
4% - 500HP |
4% - 500HP |
5% - 600HP |
5% - 750HP |
Standard 3 Phase Line Reactor Specifications:
Voltage - 600 Volts Maximum |
Temperature rise - 130° Celsius |
Cooling method - Natural convection |
Overload - 150% rated 60 Hz current overload continuous |
Enclosure - (optional) NEMA 1 |
Approvals - cUL approved |
Ratings - Nominal Inductance ± 10% @ rated current, 95% of nominal inductance @ 150% rated current, 50% of nominal inductance @ 350% of rated current |
Sound level - 2 to 18 amps: 58 dBA, 30 to 320 amps: 70 dBA, 25 to 100 amps: 64 dBA, 400 to 750 amps: 75 dBA |