Hitran's DIT Series Drive Isolation Transformers are designed and manufactured to meet the specific requirements of SCR motor drive applications. These units provide maximum isolation to components of drive systems and reduce line pollution feedback from SCR firing circuits. The 3 Phase DIT delta-wye configuration meets NEC requirements for full capacity secondary neutrals that are isolated from primary distribution systems and available for grounding. Construction is energy efficient yet rugged enough to withstand the severe electrical and mechanical conditions associated with motor drives. The KVA ratings available in the DIT Series are standard NEMA ratings which cover a wide range of DC motor sizes from 5 to 1000 horsepower. The advantages offered by these transformers include: better regulation, greater efficiency and overload capacity, lower losses and energy consumption.
|
|
|
|
| SINGLE PHASE • 60 HZ • 600 VOLT CLASS • 150°C RISE / 220°C CLASS • NEMA 1 ENCLOSED | ||||||
|
KVA
|
CATALOG
NUMBER* |
DIMENSIONS (INCHES)**
|
APPROX
WT. (LBS) |
TYPE***
MOUNTING |
||
| H | W | D | ||||
|
1
|
D10001PSF6
|
12
|
9
|
10
|
50
|
Wall
|
|
1.5
|
D10002PSF6
|
13 | 9 | 10 | 60 | Wall |
|
3
|
D10003PSF6
|
15 | 9 | 10 | 70 | Wall |
| 5 |
D10005PSF6
|
17 | 10 | 10 | 100 | Wall |
|
8
|
D10008PSF6
|
18 | 10 | 10 | 135 | Wall |
|
12
|
D10012PSH6
|
22
|
18
|
17
|
165
|
Floor
|
| 15 | D10015PSH6 | 22 | 18 | 17 | 190 | Floor |
| 20 | D10020PSH6 | 22 | 18 | 17 | 225 | Floor |
|
27
|
D10027PSH6
|
33
|
24
|
20
|
270
|
Floor
|
| 30 | D10030PSH6 | 33 | 24 | 20 | 300 | Floor |
| 34 | D10034PSH6 | 33 | 24 | 20 | 330 | Floor |
*Standard Primary and Secondary Voltages available.
(Insert code number listed for the respective letter in catalog number.)
| P = Primary Voltage. |
Code No
|
S = Secondary Voltage |
Code
No
|
|
| 208 ±5% . . . . . . . . . . . . . . . . . . . . .1 | 208.... . . . . . . . . . . . . . . . . . . . . . . .1 | |||
| 230 ±5% . . . . . . . . . . . . . . . . . . . . .2 | 230 . . . . . . . . . . . . . . . . . . . . . . . . .2 | |||
| 380 ±5% . . . . . . . . . . . . . . . . . . . . .3 | 380 . . . . . . . . . . . . . . . . . . . . . . . . .3 | |||
| 460 ±5% . . . . . . . . . . . . . . . . . . . . .4 | 460 . . . . . . . . . . . . . . . . . . . . . . . . .4 | |||
| 575 ±5% . . . . . . . . . . . . . . . . . . . . .5 | 575 . . . . . . . . . . . . . . . . . . . . . . . . .5 | |||
| 230 / 460 . . . . . . . . . . . . . . . . . . . . 6 | 230 x 460. . . . . . . . . . . . . . . . . . . . . 6 | |||
| 415 ±5% . . . . . . . . . . . . . . . . . . . . .7 | 415 . . . . . . . . . . . . . . . . . . . . . . . . .7 | |||
Lower Temperature Rise Option available at slight extra cost.
(Replace “H” in next
to last field of catalog number with code letter listed for desired temperature rise.)
| Temperature Rise/Insulation Class |
Code Letter
|
| 115°C rise / 220°C Class . . . . . . . . . . . . A | |
| 80°C rise / 220°C Class. . . . . . . . . . . . . .B | |
| 55°C rise / 220°C Class. . . . . . . . . . . . . .C | |
50 Hertz Option available at slight extra cost.
(Replace “6”in last field of catalog number with “5”)
**Dimensions listed are not to be used for construction purposes.
***Standard units are designed for floor mounting. Wall mounting brackets are available through 93KVA at slight extra cost.
THREE PHASE - DELTA PRIMARY - WYE SECONDARY - 60 HZ 600VOLT CLASS - 150°C CLASS - NEMA ENCLOSED
| HP | KVA | CATALOG NUMBER* | DIMENSIONS (INCHES)** | APPROX WT LBS |
TYPE*** MOUNTING |
||
| H | W | D | |||||
|
1.0 |
3.0 6.0 8.0 |
D30003PSF6 D30006PSF6 D30008PSH6 |
22 22 22 |
16 16 16 |
14 14 14 |
95 130 150 |
Floor Floor Floor |
| 7.5 10.0 15.0 20.0 25.0 30.0 40.0 50.0 |
12.0 15.0 20.0 27.0 34.0 40.0 51.0 63.0 |
D30012PSH6 D30015PSH6 D30020PSH6 D30027PSH6 D30034PSH6 D30040PSH6 D30051PSH6 D30063PSH6 |
26 26 26 26 26 26 26 26 |
24 24 24 24 24 24 24 24 |
20 20 20 20 20 20 20 20 |
155 170 200 235 280 310 365 410 |
Floor Floor Floor Floor Floor Floor Floor Floor |
| 60.0 75.0 100.0 125.0 |
75.0 93.0 120.0 150.0 |
D30075PSH6 D30093PSH6 D30112PSH6 D30115PSH6 |
33 33 33 33 |
28 28 28 28 |
25 25 25 25 |
515 575 710 820 |
Floor Floor Floor Floor |
| 150.0 200.0 250.0 |
180.0 220.0 280.0 |
D30118PSH6 D30122PSH6 D30128PSH6 |
48 48 48 |
40 40 40 |
32 32 32 |
1050 1250 1400 |
Floor Floor Floor |
| 300.0 400.0 500.0 |
330.0 440.0 550.0 |
D30133PSH6 D30144PSH6 D30155PSH6 |
52 52 52 |
60 60 60 |
34 34 34 |
1950 2420 2900 |
Floor Floor Floor |
| 600.0 700.0 800.0 |
660.0 760.0 870.0 |
D30166PSH6 D30176PSH6 D30187PSH6 |
54 54 54 |
60 60 60 |
40 48 48 |
3250 3500 3800 |
Floor Floor Floor |
| 900.0 1000.0 |
980.0 1100.0 |
D30198PSH6 D30211PSH6 |
72 72 |
68 68 |
48 48 |
4700 5100 |
Floor Floor |
*Standard Primary and Secondary Voltages available.
(Insert code number listed for the respective letter in catalog number.)
| P = Primary Voltage. |
Code No
|
S = Secondary Voltage |
Code
No
|
|
| 208 ±5% Delta . . . . . . . . . . . . . . . . 1 | 208Y / 120 . . . . . . . . . . . . . . . . . . . 1 | |||
| 230 ±5% Delta . . . . . . . . . . . . . . . . 2 | 230Y / 113. . . . . . . . . . . . . . . . . . . .2 | |||
| 380 ±5% Delta. . . . . . . . . . . . . . . . .3 | 380Y / 220. . . . . . . . . . . . . . . . . . . .3 | |||
| 460 ±5% Delta . . . . . . . . . . . . . . . . 4 | 460Y / 266. . . . . . . . . . . . . . . . . . . .4 | |||
| 575 ±5% Delta. . . . . . . . . . . . . . . . .5 | 575Y / 332 . . . . . . . . . . . . . . . . . . . 5 | |||
| 230 / 460 (No Taps) Delta . . . . . . . . .6 | 230 x 460Y / 133 x 266**** . . . . . . . 6 | |||
| 415 ±5% Delta . . . . . . . . . . . . . . . . 7 | 415Y / 240. . . . . . . . . . . . . . . . . . . .7 | |||
Lower Temperature Rise Option available at slight extra cost.
(Replace “H” in next to last field of catalog number with code letter listed
for desired temperature rise.)
| Temperature Rise/Insulation Class | Code Letter |
| 115°C rise / 220°C Class | F |
| 80 °C rise / 220°C Class | B |
| 55 °C rise / 220°C Class | A |
50 Hertz Option available at slight extra cost.
(Replace “6”in last field of catalog number with “5”)
**Dimensions listed are not to be used for construction purposes.
***Standard units are designed for floor mounting. Wall mounting brackets available through 93KVA at slight extra cost.
****Primary or Secondary Code #6 is available at Standard Price through 93 KVA only.
Please consult the factory for prices on larger units.